Julien Favre

Publications | Mémoires et thèses

La recherche avancée est accessible via Serval

Les publications peuvent être gérées en accédant à Serval via MyUnil


108 publications

2024 | 2023 | 2022 | 2021 | 2020 | 2019 | 2018 | 2017 | 2016 | 2015 | 2014 | 2013 | 2012 | 2011 | 2010 | 2009 | 2008 | 2007 | 2006 |
 
Morphological and histological features of thicker cartilage at the posterior medial femoral condyle in advanced knee osteoarthritis.
Geurts J., Andrey F., Favre J., Hügle T., Omoumi P., 2024/09. Osteoarthritis and cartilage open, 6 (3) p. 100502. Peer-reviewed.
Changes in spinal motor behaviour are associated with reduction in disability in chronic low back pain: A longitudinal cohort study with 1-year follow-up.
Christe G., Benaim C., Jolles B.M., Favre J., 2024/08. European journal of pain, 28 (7) pp. 1116-1126. Peer-reviewed.
 
Intra- and inter-operator reliability of three-dimensional preoperative planning in total knee arthroplasty.
Cosendey K., Moerenhout K., Stanovici J., Jolles B.M., Favre J., 2024/08. Archives of orthopaedic and trauma surgery, 144 (8) pp. 3625-3630. Peer-reviewed.
Simultaneous Evaluation of Bone Cut and Implant Placement Accuracy in Robotic-Assisted Total Knee Arthroplasty.
Cosendey K., Stanovici J., Cadas H., Omoumi P., Jolles B.M., Favre J., 2024/02/25. Journal of clinical medicine, 13 (5) p. 1293. Peer-reviewed.
Accuracy and Reliability of Pelvimetry Measures Obtained by Manual or Automatic Labeling of Three-Dimensional Pelvic Models.
Hêches J., Marcadent S., Fernandez A., Adjahou S., Meuwly J.Y., Thiran J.P., Desseauve D., Favre J., 2024/01/25. Journal of clinical medicine, 13 (3). Peer-reviewed.
Slowing gait during turning: how volition of modifying walking speed affects the gait pattern in healthy adults.
Madrid J., Benning L., Selig M., Ulrich B., Jolles B.M., Favre J., Benninger D.H., 2024. Frontiers in human neuroscience, 18 p. 1269772. Peer-reviewed.
The relationships between spinal amplitude of movement, pain and disability in low back pain: A systematic review and meta-analysis.
Nzamba J., Van Damme S., Favre J., Christe G., 2024/01. European journal of pain, 28 (1) pp. 37-53. Peer-reviewed.
Rehabilitation for Musculoskeletal Disorders: The Emergence of Serious Games and the Promise of Personalized Versions Using Artificial Intelligence.
Favre J., Cantaloube A., Jolles B.M., 2023/08/15. Journal of clinical medicine, 12 (16) p. 5310. Peer-reviewed.
 
AB1193 Is combining better than single gait parameter changes for people with medial of knee osteoarthritis? A study on the kinetic changes induced by gait retraining
Pereira L. C., Ulrich B., Runhaar J., Bierma-Zeinstra S. M. A., Jolles B. M., Favre J., 2023/06., EULAR 2023 European Congress of Rheumatology, 31 May - 3 June pp. 1826-1827 dans Scientific Abstracts.
Improved accuracy and precision of fat-suppressed isotropic 3D T2 mapping MRI of the knee with dictionary fitting and patch-based denoising.
Kuhn S., Bustin A., Lamri-Senouci A., Rumac S., Ledoux J.B., Colotti R., Bastiaansen JAM, Yerly J., Favre J., Omoumi P. et al., 2023/05/22. European radiology experimental, 7 (1) p. 25. Peer-reviewed.
Walking with Different Insoles Changes Lower-Limb Biomechanics Globally in Patients with Medial Knee Osteoarthritis.
Jaques G., Ulrich B., Hoffmann L., Jolles B.M., Favre J., 2023/03/03. Journal of clinical medicine, 12 (5) p. 2016. Peer-reviewed.
Reduction in pain-related fear is not associated with improvement in spinal biomechanics but with decrease in movement-evoked pain in patients with chronic low back pain.
Christe G., Benaim C., Luthi F., Jolles B.M., Favre J., 2023/03. Pain practice, 23 (3) pp. 290-300. Peer-reviewed.
Ten-year follow-up of a total knee prosthesis combining multi-radius, ultra-congruency, posterior-stabilization and mobile-bearing insert shows long-lasting clinically relevant improvements in pain, stiffness, function and stability.
Cosendey K., Eudier A., Fleury N., Pereira L.C., Favre J., Jolles B.M., 2023/03. Knee surgery, sports traumatology, arthroscopy, 31 (3) pp. 1043-1052. Peer-reviewed.
 
3-D Freehand Ultrasound Calibration Using a Tissue-Mimicking Phantom With Parallel Wires.
Marcadent S., Heches J., Favre J., Desseauve D., Thiran J.P., 2023/01. Ultrasound in medicine & biology, 49 (1) pp. 165-177. Peer-reviewed.
Diverse parameters of ambulatory knee moments differ with medial knee osteoarthritis severity and are combinable into a severity index.
Ulrich B., Erhart-Hledik J.C., Asay J.L., Omoumi P., Andriacchi T.P., Jolles B.M., Favre J., 2023. Frontiers in bioengineering and biotechnology, 11 p. 1176471. Peer-reviewed.
Spatiotemporal parameters during turning gait maneuvers of different amplitudes in young and elderly healthy adults: A descriptive and comparative study.
Madrid J., Ulrich B., Santos A.N., Jolles B.M., Favre J., Benninger D.H., 2023/01. Gait & posture, 99 pp. 152-159. Peer-reviewed.
Walking with shorter stride length could improve knee kinetics of patients with medial knee osteoarthritis.
Ulrich B., Pereira L.C., Jolles B.M., Favre J., 2023/01. Journal of biomechanics, 147 p. 111449. Peer-reviewed.
MRI signal and morphological alterations of the suprapatellar fat pad in asymptomatic subjects: are these normal variants?
Cosentino A., Richard R., Baron M., Demondion X., Favre J., Omoumi P., 2022/10. Skeletal radiology, 51 (10) pp. 1995-2007. Peer-reviewed.
Between/within-session reliability of spinal kinematic and lumbar muscle activity measures in patients with chronic low back pain and asymptomatic individuals.
Christe G., Jolles B.M., Favre J., 2022/06. Gait & posture, 95 pp. 100-108. Peer-reviewed.
Effect of very large body mass loss on energetics, mechanics and efficiency of walking in adults with obesity: mass-driven versus behavioural adaptations.
Malatesta D., Favre J., Ulrich B., Hans D., Suter M., Favre L., Fernández Menéndez A., 2022/02. The Journal of physiology, 600 (4) pp. 979-996. Peer-reviewed.
An Expert-Supervised Registration Method for Multiparameter Description of the Knee Joint Using Serial Imaging.
Babel H., Omoumi P., Cosendey K., Stanovici J., Cadas H., Jolles B.M., Favre J., 2022/01/22. Journal of clinical medicine, 11 (3) p. 548. Peer-reviewed.
 
Association between changes in the knee adduction moment and changes in knee pain and function in response to non-surgical biomechanical interventions for medial knee osteoarthritis: a systematic review.
Pereira L.C., Runhaar J., Favre J., Jolles B.M., Bierma-Zeinstra S., 2021/12. European journal of physical and rehabilitation medicine, 57 (6) pp. 948-958. Peer-reviewed.
 
Proximal tibial osteophyte volumes are correlated spatially and with knee alignment: a quantitative analysis suggesting the influence of biochemical and mechanical factors in the development of osteophytes.
Omoumi P., Schuler A., Babel H., Stoffel C., Jolles B.M., Favre J., 2021/12. Osteoarthritis and cartilage, 29 (12) pp. 1691-1700. Peer-reviewed.
 
Effects of step width modifications on the ambulatory kinetics in patients with medial knee osteoarthritis
Pereira L.C., Ulrich B., Runhaar J., Bierma-Zeinstra S, Jolles B.M., Favre J., 2021/09/11. Osteoarthritis and Cartilage. Peer-reviewed.
 
Ossification of the acetabular rim: a highly prevalent finding in asymptomatic non-osteoarthritic hips of all ages.
Valente C., Haefliger L., Favre J., Omoumi P., 2021/09. European radiology, 31 (9) pp. 6802-6809. Peer-reviewed.
 
Bone Cuts Accuracy of a System for Total Knee Arthroplasty including an Active Robotic Arm.
Cosendey K., Stanovici J., Mahlouly J., Omoumi P., Jolles B.M., Favre J., 2021/08/20. Journal of clinical medicine, 10 (16) p. 3714. Peer-reviewed.
 
Longitudinal changes in tibial and femoral cartilage thickness are associated with baseline ambulatory kinetics and cartilage oligomeric matrix protein (COMP) measures in an asymptomatic aging population.
Erhart-Hledik J.C., Chehab E.F., Asay J.L., Favre J., Chu C.R., Andriacchi T.P., 2021/05. Osteoarthritis and cartilage, 29 (5) pp. 687-696. Peer-reviewed.
 
Longitudinal Femoral Cartilage T2 Relaxation Time and Thickness Changes with Fast Sequential Radiographic Progression of Medial Knee Osteoarthritis-Data from the Osteoarthritis Initiative (OAI).
Edd S.N., Omoumi P., Jolles B.M., Favre J., 2021/03/21. Journal of clinical medicine, 10 (6) p. 1294. Peer-reviewed.
 
Relationship between psychological factors and spinal motor behaviour in low back pain: a systematic review and meta-analysis.
Christe G., Crombez G., Edd S., Opsommer E., Jolles B.M., Favre J., 2021/03/01. Pain, 162 (3) pp. 672-686. Peer-reviewed.
Analyzing Femorotibial Cartilage Thickness Using Anatomically Standardized Maps: Reproducibility and Reference Data.
Favre J., Babel H., Cavinato A., Blazek K., Jolles B.M., Andriacchi T.P., 2021/01/26. Journal of clinical medicine, 10 (3) p. 461. Peer-reviewed.
Three-Dimensional Quantification of Bone Mineral Density in the Distal Femur and Proximal Tibia Based on Computed Tomography: In Vitro Evaluation of an Extended Standardization Method.
Babel H., Omoumi P., Cosendey K., Cadas H., Jolles B.M., Favre J., 2021/01/05. Journal of clinical medicine, 10 (1) p. 160. Peer-reviewed.
 
A Registration Method for Three-Dimensional Analysis of Bone Mineral Density in the Proximal Tibia.
Babel H., Wägeli L., Sonmez B., Thiran J.P., Omoumi P., Jolles B.M., Favre J., 2021/01/01. Journal of biomechanical engineering, 143 (1) p. 014502. Peer-reviewed.
Assessing feasibility and maternal acceptability of a biomechanically-optimized supine birth position: A pilot study.
Bouille L., Sichitiu J., Favre J., Desseauve D., 2021. PloS one, 16 (9) pp. e0257285. Peer-reviewed.
Could Gait Biomechanics Become a Marker of Atypical Neuronal Circuitry in Human Development?-The Example of Autism Spectrum Disorder.
Jequier Gygax M., Maillard A.M., Favre J., 2021. Frontiers in bioengineering and biotechnology, 9 p. 624522. Peer-reviewed.
Patients With Chronic Low Back Pain Have an Individual Movement Signature: A Comparison of Angular Amplitude, Angular Velocity and Muscle Activity Across Multiple Functional Tasks.
Christe G., Aussems C., Jolles B.M., Favre J., 2021. Frontiers in bioengineering and biotechnology, 9 p. 767974. Peer-reviewed.
 
Decreasing the ambulatory knee adduction moment without increasing the knee flexion moment individually through modifications in footprint parameters: A feasibility study for a dual kinetic change in healthy subjects.
Ulrich B., Cosendey K., Jolles B.M., Favre J., 2020/10/09. Journal of biomechanics, 111 p. 110004. Peer-reviewed.
 
New insight on the subchondral bone and cartilage functional unit: Bone mineral density and cartilage thickness are spatially correlated in non-osteoarthritic femoral condyles.
Babel H., Omoumi P., Andriacchi T.P., Jolles B.M., Favre J., 2020/09. Osteoarthritis and cartilage open, 2 (3) p. 100079. Peer-reviewed.
 
Modifying Stride Length in Isolation and in Combination With Foot Progression Angle and Step Width Can Improve Knee Kinetics Related to Osteoarthritis; A Preliminary Study in Healthy Subjects.
Edd S.N., Bennour S., Ulrich B., Jolles B.M., Favre J., 2020/07/01. Journal of biomechanical engineering, 142 (7) p. 074505. Peer-reviewed.
 
Lumbar and thoracic kinematics during step-up: Comparison of three-dimensional angles between patients with chronic low back pain and asymptomatic individuals.
Christe G., Rochat V., Jolles B.M., Favre J., 2020/06. Journal of orthopaedic research, 38 (6) pp. 1248-1256. Peer-reviewed.
 
Changes in ambulatory knee adduction moment with lateral wedge insoles differ with respect to the natural foot progression angle.
Ulrich B., Hoffmann L., Jolles B.M., Favre J., 2020/04/16. Journal of biomechanics, 103 p. 109655. Peer-reviewed.
 
Changes in lower limb biomechanics when following floor-projected foot placement visual cues for gait rehabilitation.
Edd S.N., Vida Martins N., Bennour S., Ulrich B., Jolles B.M., Favre J., 2020/03. Gait & posture, 77 pp. 293-299. Peer-reviewed.
Quantification in Musculoskeletal Imaging Using Computational Analysis and Machine Learning: Segmentation and Radiomics.
Bach Cuadra M., Favre J., Omoumi P., 2020/02. Seminars in musculoskeletal radiology, 24 (1) pp. 50-64. Peer-reviewed.
 
Longitudinal Changes in the Total Knee Joint Moment After Anterior Cruciate Ligament Reconstruction Correlate With Cartilage Thickness Changes.
Erhart-Hledik J., Chu C., Asay J., Favre J., Andriacchi T., 2019/07. Journal of orthopaedic research, 37 (7) pp. 1546-1554. Peer-reviewed.
 
Gait events during turning can be detected using kinematic features originally proposed for the analysis of straight-line walking.
Ulrich B., Santos A.N., Jolles B.M., Benninger D.H., Favre J., 2019/06/25. Journal of biomechanics, 91 pp. 69-78. Peer-reviewed.
 
Comprehensive description of T2 value spatial variations in non-osteoarthritic femoral cartilage using three-dimensional registration of morphological and relaxometry data.
Edd S.N., Babel H., Kerkour N., Jolles B.M., Omoumi P., Favre J., 2019/06. The Knee, 26 (3) pp. 555-563. Peer-reviewed.
 
Relationships between cartilage thickness and subchondral bone mineral density in non-osteoarthritic and severely osteoarthritic knees: In vivo concomitant 3D analysis using CT arthrography.
Omoumi P., Babel H., Jolles B.M., Favre J., 2019/04. Osteoarthritis and cartilage, 27 (4) pp. 621-629. Peer-reviewed.
 
Corrigendum to "Chronic low back pain patients walk with locally altered spinal kinematics" [J. Biomech. 60 (2017) 211-218].
Christe G., Kade F., Jolles B.M., Favre J., 2019/01/23..
Gait analysis following single-shot hyaluronic acid supplementation: a pilot randomized double-blinded controlled trial.
Pereira L.C., Schweizer C., Moufarrij S., Krähenbühl S.M., Favre J., Gremion G., Applegate L.A., Jolles B.M., 2019. Pilot and feasibility studies, 5 p. 56. Peer-reviewed.
 
Modeling knee osteoarthritis pathophysiology using an integrated joint system (IJS): a systematic review of relationships among cartilage thickness, gait mechanics, and subchondral bone mineral density.
Edd S.N., Omoumi P., Andriacchi T.P., Jolles B.M., Favre J., 2018/11. Osteoarthritis and cartilage, 26 (11) pp. 1425-1437. Peer-reviewed.
Cartilage can be thicker in advanced osteoarthritic knees: a tridimensional quantitative analysis of cartilage thickness at posterior aspect of femoral condyles.
Omoumi P., Babel H., Jolles B.M., Favre J., 2018/07. The British journal of radiology, 91 (1087) p. 20170729. Peer-reviewed.
 
Effect of lateral wedge length on ambulatory knee kinetics.
Fischer A.G., Ulrich B., Hoffmann L., Jolles B.M., Favre J., 2018/06. Gait & posture, 63 pp. 114-118. Peer-reviewed.
 
Spatial variations in non-osteoarthritic tibial cartilage T2 relaxation time and cartilage thickness
Edd S.N., Babel H., Pereira L.C., Jolles B.M., Omoumi P., Favre J., 2018/04. pp. S462-S463 dans Osteoarthritis and Cartilage.
 
A gait retraining system using augmented-reality to modify footprint parameters: Effects on lower-limb sagittal-plane kinematics.
Bennour S., Ulrich B., Legrand T., Jolles B.M., Favre J., 2018/01/03. Journal of biomechanics, 66 pp. 26-35. Peer-reviewed.
 
Anatomically Standardized Maps Reveal Distinct Patterns of Cartilage Thickness With Increasing Severity of Medial Compartment Knee Osteoarthritis.
Favre J., Erhart-Hledik J.C., Blazek K., Fasel B., Gold G.E., Andriacchi T.P., 2017/11. Journal of orthopaedic research, 35 (11) pp. 2442-2451. Peer-reviewed.
 
Quantitative regional and sub-regional analysis of femoral and tibial subchondral bone mineral density (sBMD) using computed tomography (CT): comparison of non-osteoarthritic (OA) and severe OA knees.
Omoumi P., Babel H., Jolles B.M., Favre J., 2017/11. Osteoarthritis and cartilage, 25 (11) pp. 1850-1857. Peer-reviewed.
 
Chronic low back pain patients walk with locally altered spinal kinematics.
Christe G., Kade F., Jolles B.M., Favre J., 2017/07/26. Journal of biomechanics, 60 pp. 211-218. Peer-reviewed.
 
Speed, age, sex, and body mass index provide a rigorous basis for comparing the kinematic and kinetic profiles of the lower extremity during walking.
Chehab E.F., Andriacchi T.P., Favre J., 2017/06/14. Journal of biomechanics, 58 pp. 11-20. Peer-reviewed.
 
Altered gait mechanics and elevated serum pro-inflammatory cytokines in asymptomatic patients with MRI evidence of knee cartilage loss.
Edd S.N., Favre J., Blazek K., Omoumi P., Asay J.L., Andriacchi T.P., 2017/06. Osteoarthritis and cartilage, 25 (6) pp. 899-906. Peer-reviewed.
Qualitative analysis of foot intersegment coordination in the sagittal plane following surgery for end-stage ankle osteoarthrosis.
Chopra S., Favre J., Crevoisier X., 2017/06. Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 35 (6) pp. 1304-1310. Peer-reviewed.
Gait analysis of patients with knee osteoarthritis highlights a pathological mechanical pathway and provides a basis for therapeutic interventions
Favre J., Jolles B. M., 2016/10/26. EFORT Open Reviews, 1 (10) pp. 368-374. Peer-reviewed.
 
General scheme to reduce the knee adduction moment by modifying a combination of gait variables.
Favre J., Erhart-Hledik J.C., Chehab E.F., Andriacchi T.P., 2016/09. Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 34 (9) pp. 1547-1556. Peer-reviewed.
 
Baseline ambulatory knee kinematics are associated with changes in cartilage thickness in osteoarthritic patients over 5 years.
Favre J., Erhart-Hledik J.C., Chehab E.F., Andriacchi T.P., 2016/06/14. Journal of biomechanics, 49 (9) pp. 1859-1864. Peer-reviewed.
 
Modification of Knee Flexion Angle Has Patient-Specific Effects on Anterior Cruciate Ligament Injury Risk Factors During Jump Landing.
Favre J., Clancy C., Dowling A.V., Andriacchi T.P., 2016/06. The American journal of sports medicine, 44 (6) pp. 1540-1546. Peer-reviewed.
 
Multi-segment analysis of spinal kinematics during sit-to-stand in patients with chronic low back pain.
Christe G., Redhead L., Legrand T., Jolles B.M., Favre J., 2016. Journal of Biomechanics, 49 (10) pp. 2060-2067. Peer-reviewed.
 
Outcome of ankle arthrodesis and total ankle replacement for ankle arthrosis in terms of gait variability
Chopra Swati, Rouhani Hossein, Moerenhout Kevin, Favre Julien, Aminian Kamiar, Crevoisier Xavier, 2015/09/21. Journal of Biomedical Engineering and Informatics, 2 (1) p. 31. Peer-reviewed.
 
Alterations in knee kinematics after partial medial meniscectomy are activity dependent.
Edd S.N., Netravali N.A., Favre J., Giori N.J., Andriacchi T.P., 2015/06. The American journal of sports medicine, 43 (6) pp. 1399-1407. Peer-reviewed.
 
Relationship Between Knee Mechanics and Time Since Injury in ACL-Deficient Knees Without Signs of Osteoarthritis.
Zabala M.E., Favre J., Andriacchi T.P., 2015/05. The American journal of sports medicine, 43 (5) pp. 1189-1196. Peer-reviewed.
 
Effects of high heel wear and increased weight on the knee during walking.
Titchenal M.R., Asay J.L., Favre J., Andriacchi T.P., Chu C.R., 2015/03. Journal of orthopaedic research : official publication of the Orthopaedic Research Society, 33 (3) pp. 405-411. Peer-reviewed.
A systems view of risk factors for knee osteoarthritis reveals insights into the pathogenesis of the disease.
Andriacchi T.P., Favre J., Erhart-Hledik J.C., Chu C.R., 2015. Annals of Biomedical Engineering, 43 (2) pp. 376-387. Peer-reviewed.
 
An inertial sensor-based system for spatio-temporal analysis in classic cross-country skiing diagonal technique.
Fasel B., Favre J., Chardonnens J., Gremion G., Aminian K., 2015. Journal of Biomechanics, 48 (12) pp. 3199-3205. Peer-reviewed.
 
How to prevent venous cannula orifice obstruction during extracorporeal circulation.
Abdel-Sayed S., Favre J., von Segesser L.K., 2015. Perfusion, 30 (3) pp. 187-194. Peer-reviewed.
 
New insight in the relationship between regional patterns of knee cartilage thickness, osteoarthritis disease severity, and gait mechanics.
Erhart-Hledik J.C., Favre J., Andriacchi T.P., 2015. Journal of Biomechanics, 48 (14) pp. 3868-3875. Peer-reviewed.
 
Baseline knee adduction and flexion moments during walking are both associated with 5 year cartilage changes in patients with medial knee osteoarthritis.
Chehab E.F., Favre J., Erhart-Hledik J.C., Andriacchi T.P., 2014/11. Osteoarthritis and cartilage, 22 (11) pp. 1833-1839. Peer-reviewed.
 
A wearable system for multi-segment foot kinetics measurement.
Rouhani H., Favre J., Crevoisier X., Aminian K., 2014/05/07. Journal of biomechanics, 47 (7) pp. 1704-1711. Peer-reviewed.
 
Camera Networks for Healthcare, Teleimmersion, and Surveillance
Chen C.H., Favre J., Kurillo G., Andriacchi T.P., Bajcsy R., Chellappa R., 2014/05. Computer, 47 (5) pp. 26-36. Peer-reviewed.
 
Age and obesity alter the relationship between femoral articular cartilage thickness and ambulatory loads in individuals without osteoarthritis.
Blazek K., Favre J., Asay J., Erhart-Hledik J., Andriacchi T.P., 2014/03. Journal of orthopaedic research, 32 (3) pp. 394-402. Peer-reviewed.
 
Age-related differences in sagittal-plane knee function at heel-strike of walking are increased in osteoarthritic patients.
Favre J., Erhart-Hledik J.C., Andriacchi T.P., 2014/03. Osteoarthritis and cartilage, 22 (3) pp. 464-471. Peer-reviewed.
 
Measurement of the dynamics in ski jumping using a wearable inertial sensor-based system.
Chardonnens J., Favre J., Cuendet F., Gremion G., Aminian K., 2014. Journal of Sports Sciences, 32 (6) pp. 591-600. Peer-reviewed.
 
Performance increase in venous drainage for mini-invasive heart surgery: superiority of self-expanding cannulas.
Belkoniene M., Abdel-Sayed S., Favre J., von Segesser L.K., 2014. Innovations (philadelphia, Pa.), 9 (4) pp. 297-301. Peer-reviewed.
 
The nature of in vivo mechanical signals that influence cartilage health and progression to knee osteoarthritis.
Andriacchi T.P., Favre J., 2014. Current Rheumatology Reports, 16 (11) p. 463.
 
Patterns of femoral cartilage thickness are different in asymptomatic and osteoarthritic knees and can be used to detect disease-related differences between samples.
Favre J., Scanlan S.F., Erhart-Hledik J.C., Blazek K., Andriacchi T.P., 2013/10/01. Journal of biomechanical engineering, 135 (10) pp. 101002-101010. Peer-reviewed.
 
Functional testing provides unique insights into the pathomechanics of femoroacetabular impingement and an objective basis for evaluating treatment outcome.
Rylander J., Shu B., Favre J., Safran M., Andriacchi T.P., 2013/09. Journal of orthopaedic research, 31 (9) pp. 1461-1468. Peer-reviewed.
 
The relationship between peak knee extension at heel-strike of walking and the location of thickest femoral cartilage in ACL reconstructed and healthy contralateral knees.
Scanlan S.F., Favre J., Andriacchi T.P., 2013/03/15. Journal of biomechanics, 46 (5) pp. 849-854. Peer-reviewed.
 
Three-dimensional knee moments of ACL reconstructed and control subjects during gait, stair ascent, and stair descent.
Zabala M.E., Favre J., Scanlan S.F., Donahue J., Andriacchi T.P., 2013/02/01. Journal of biomechanics, 46 (3) pp. 515-520. Peer-reviewed.
 
A system to measure the kinematics during the entire ski jump sequence using inertial sensors.
Chardonnens J., Favre J., Cuendet F., Gremion G., Aminian K., 2013. Journal of Biomechanics, 46 (1) pp. 56-62. Peer-reviewed.
 
Characterization of lower-limbs inter-segment coordination during the take-off extension in ski jumping.
Chardonnens J., Favre J., Cuendet F., Gremion G., Aminian K., 2013. Human Movement Science, 32 (4) pp. 741-752. Peer-reviewed.
 
Prevention of Caval Collapse During Venous Drainage for CPB.
Abdel-Sayed S., Favre J., Taub S., von Segesser L.K., 2013. Asaio Journal, 59 (1) pp. 46-51. Peer-reviewed.
 
A relationship between mechanically-induced changes in serum cartilage oligomeric matrix protein (COMP) and changes in cartilage thickness after 5 years.
Erhart-Hledik J.C., Favre J., Asay J.L., Smith R.L., Giori N.J., Mündermann A., Andriacchi T.P., 2012/11. Osteoarthritis and cartilage, 20 (11) pp. 1309-1315. Peer-reviewed.
 
Characterization of thigh and shank segment angular velocity during jump landing tasks commonly used to evaluate risk for ACL injury.
Dowling A.V., Favre J., Andriacchi T.P., 2012/09. Journal of biomechanical engineering, 134 (9) p. 091006. Peer-reviewed.
 
An effortless procedure to align the local frame of an inertial measurement unit to the local frame of another motion capture system.
Chardonnens J., Favre J., Aminian K., 2012/08/31. Journal of biomechanics, 45 (13) pp. 2297-2300. Peer-reviewed.
 
Inertial sensor-based feedback can reduce key risk metrics for anterior cruciate ligament injury during jump landings.
Dowling A.V., Favre J., Andriacchi T.P., 2012/05. The American journal of sports medicine, 40 (5) pp. 1075-1083. Peer-reviewed.
 
A neural network model to predict knee adduction moment during walking based on ground reaction force and anthropometric measurements.
Favre J., Hayoz M., Erhart-Hledik J.C., Andriacchi T.P., 2012/02/23. Journal of biomechanics, 45 (4) pp. 692-698. Peer-reviewed.
 
A comparison between joint coordinate system and attitude vector for multi-segment foot kinematics.
Rouhani H., Favre J., Crevoisier X., Jolles B.M., Aminian K., 2012. Journal of Biomechanics, 45 (11) pp. 2041-2045. Peer-reviewed.
 
Automatic measurement of key ski jumping phases and temporal events with a wearable system.
Chardonnens J., Favre J., Le Callennec B., Cuendet F., Gremion G., Aminian K., 2012. Journal of Sports Sciences, 30 (1) pp. 53-61. Peer-reviewed.
 
Characterizing the impact of minor cannula design modification.
Abdel-Sayed S., Favre J., Segesser L.K., 2012. International Journal of Artificial Organs, 35 (2) pp. 132-138. Peer-reviewed.
 
Measurement of multi-segment foot joint angles during gait using a wearable system.
Rouhani H., Favre J., Crevoisier X., Aminian K., 2012. Journal of Biomechanical Engineering, 134 (6) p. 061006. Peer-reviewed.
 
Multi-segment foot kinematics after total ankle replacement and ankle arthrodesis during relatively long-distance gait.
Rouhani H., Favre J., Aminian K., Crevoisier X., 2012. Gait and Posture, 36 (3) pp. 561-566. Peer-reviewed.
 
A wearable system to assess risk for anterior cruciate ligament injury during jump landing: measurements of temporal events, jump height, and sagittal plane kinematics.
Dowling A.V., Favre J., Andriacchi T.P., 2011/07. Journal of biomechanical engineering, 133 (7) p. 071008. Peer-reviewed.
 
Ambulatory measurement of ankle kinetics for clinical applications.
Rouhani H., Favre J., Crevoisier X., Aminian K., 2011. Journal of Biomechanics, 44 (15) pp. 2712-2718. Peer-reviewed.
 
Outcome evaluation of ankle osteoarthritis treatments: plantar pressure analysis during relatively long-distance walking.
Rouhani H., Crevoisier X., Favre J., Aminian K., 2011. Clinical Biomechanics, 26 (4) pp. 397-404. Peer-reviewed.
 
Segmentation of foot and ankle complex based on kinematic criteria.
Rouhani H., Favre J., Crevoisier X., Jolles B.M., Aminian K., 2011. Computer Methods In Biomechanics and Biomedical Engineering, 14 (9) pp. 773-781. Peer-reviewed.
 
Ambulatory assessment of 3D ground reaction force using plantar pressure distribution.
Rouhani H., Favre J., Crevoisier X., Aminian K., 2010. Gait and Posture, 32 (3) pp. 311-316.
 
Evaluation of a mixed approach combining stationary and wearable systems to monitor gait over long distance.
Favre J., Crevoisier X., Jolles B.M., Aminian K., 2010. Journal of Biomechanics, 43 (11) pp. 2196-2202. Peer-reviewed.
 
Functional calibration procedure for 3D knee joint angle description using inertial sensors.
Favre J., Aissaoui R., Jolles B.M., de Guise J.A., Aminian K., 2009. Journal of Biomechanics, 42 (14) pp. 2330-2335. Peer-reviewed.
 
Ambulatory measurement of 3D knee joint angle.
Favre J., Jolles B.M., Aissaoui R., Aminian K., 2008. Journal of Biomechanics, 41 (5) pp. 1029-1035. Peer-reviewed.
 
New bench test for venous cannula performance assessment.
Abdel-Sayed S., Favre J., Horisberger J., Taub S., Hayoz D., von Segesser L.K., 2007. Perfusion, 22 (6) pp. 411-416. Peer-reviewed.
 
A new ambulatory system for comparative evaluation of the three-dimensional knee kinematics, applied to anterior cruciate ligament injuries.
Favre J., Luthi F., Jolles B.M., Siegrist O., Najafi B., Aminian K., 2006/07. Knee surgery, sports traumatology, arthroscopy, 14 (7) pp. 592-604. Peer-reviewed.
 
Quaternion based fusion of gyroscopes and accelerometers to improve 3D angle measurement
Favre J., Jolles B.M., Siegrist O., Aminian K., 2006. Journal Electronics Letters, 42 (11) pp. 612-614. Peer-reviewed.
Partagez:
Unicentre - CH-1015 Lausanne
Suisse
Tél. +41 21 692 11 11
Swiss University