Influence of detector collimation on SNR in four different MDCT scanners using a reconstructed slice thickness of 5 mm
Verdun F. R., Noel A., Meuli R., Pachoud M., Monnin P., Valley J. F., Schnyder P., Denys A., 2004. European Radiology, 14 (10) pp. 1866-1872. Peer-reviewed.
Management of patient dose and image noise in routine pediatric CT abdominal examinations.
Verdun F.R., Lepori D., Monnin P., Valley J.F., Schnyder P., Gudinchet F., 2004. European Radiology, 14 (5) pp. 835-841. Peer-reviewed.
 
Quantitative characterization of edge enhancement in phase contrast x-ray imaging
Monnin P., Bulling S., Hoszowska J., Valley J. F., Meuli R., Verdun F. R., 2004. Medical Physics, 31 (6) pp. 1372-1383. Peer-reviewed.
 
Phase Contrast in X-Ray Diagnostic Imaging
Monnin P., Meuli R., Valley JF., Verdun FR, 2003/06. dans 2003.06.26-28 SSR Imagerie et communication. 90ème Congrès annuel de la Société Suisse de Radiologie, Lucerne, Switzerland..
 
CT arthrography of the glenohumeral joint: CT fluoroscopy versus conventional CT and fluoroscopy--comparison of image-guidance techniques.
Binkert C.A., Verdun F.R., Zanetti M., Pfirrmann C.W., Hodler J., 2003. Radiology, 229 (1) pp. 153-8. Peer-reviewed.
 
Evaluation of peripheral arterial bypass grafts with multi-detector row CT angiography: comparison with duplex US and digital subtraction angiography.
Willmann J.K., Mayer D., Banyai M., Desbiolles L.M., Verdun F.R., Seifert B., Marincek B., Weishaupt D., 2003. Radiology, 229 (2) pp. 465-74. Peer-reviewed.
 
Influence of scatter reduction method and monochromatic beams on image quality and dose in mammography.
Moeckli R., Verdun F.R., Fiedler S., Pachoud M., Bulling S., Schnyder P., Valley J.F., 2003. Medical Physics, 30 (12) pp. 3156-3164. Peer-reviewed.
 
Detection of low-contrast objects: experimental comparison of single- and multi-detector row CT with a phantom.
Verdun F.R., Denys A., Valley J.F., Schnyder P., Meuli R.A., 2002/12. pp. 426-431 dans RSNA 2002 Radiological Society of North America, 88th Scientific Assembly and Annual Meeting. Peer-reviewed.
 
A Training Tool to Reduce Personal Exposure during Interventional Procedures
Verdun F., Stauffer C., Schnyder P., Valley J.F., Wicky S., 2002/06. dans RSNA 2002 Radiological Society of North America, 88th Scientific Assembly and Annual Meeting.
 
Assessment of the image contrast improvement and dose reduction in mammography with synchrotron radiation compared to standard units
Moeckli R., Verdun F.R., Fiedler S., Pachoud M., Hessler C., Meuli R., Valley J.F., 2001. Nuclear Instruments & Methods in Physics Research Section A-Accelerators Spectrometers Detectors and Associated Equipment, 467 (Part 2) pp. 1349-1352. Peer-reviewed.
 
Effect of scatter on image quality in synchrotron radiation mammography
Moeckli Raphaël, 2001. Proceedings of SPIE- The International Society for Optical Engineering.
 
Real-time flat-panel pixel imaging system and control for X-ray and neutron detection
Chapuy S., Dimcovski M., Dimcovski Z., Lehmann E. H., Pachoud M., Valley J. F., Verdun F. R., Vontobel P., 2001. Ieee Transactions on Nuclear Science, 48 (6) pp. 2357-2364. Peer-reviewed.
 
A real-time flat-panel X-ray pixel imaging system for low-dose medical diagnostics and craniofacial applications
Chapuy S., Dimcovski D., Dimcovski Z., Grigoriev E., Grob E., Ligier Y., Pachoud M., Riondel F., Rufenacht D., Sayegh C. et al., 2000. Journal of Craniofacial Surgery, 11 (1) pp. 10-16. Peer-reviewed.
 
Dose and image quality characterisation of CT units
Verdun F. R., Meuli R. A., Bucher G., Noel A., Stines J., Schnyder P., Valley J. F., 2000. Radiation Protection Dosimetry, 90 (1-2) pp. 193-196. Peer-reviewed.
 
New screen-film characterisation by means of objective and subjective methods
Pachoud M., Verdun F.R., Moeckli R., Hessler C., Lepori D., Valley J.F., 2000. Radiation Protection Dosimetry, 90 (1-2) pp. 177-180. Peer-reviewed.
 
Objective comparison of image quality and dose between conventional and synchrotron radiation mammography.
Moeckli R., Verdun F.R., Fiedler S., Pachoud M., Schnyder P., Valley J.F., 2000. Physics in medicine and biology, 45 (12) pp. 3509-23. Peer-reviewed.
 
Quality assurance programme desirable for a radiological film digitiser
Verdun F.R., Hoeschen C., Pachoud M., Moeckli R., Schnyder P., Valley J.F., 2000. Radiation Protection Dosimetry, 90 (1-2) pp. 253-258. Peer-reviewed.
 
Radiation doses in computed tomography: pitfalls in comparing CT to chest X-ray
Verdun F., Meuli R., 2000. BMJ, e-only.
 
The optimisation of lumbar spine AP radiography using a realistic computer model
Dance D. R., Mcvey G. H., Sandborg M., Carlsson G. A., Verdun F. R., 2000. Radiation Protection Dosimetry, 90 (1-2) pp. 207-210. Peer-reviewed.
 
Using 80 kVp versus 120 kVp in perfusion CT measurement of regional cerebral blood flow.
Wintermark M., Maeder P., Verdun F.R., Thiran J.P., Valley J.F., Schnyder P., Meuli R., 2000. AJNR. American journal of neuroradiology, 21 (10) pp. 1881-4. Peer-reviewed.
 
Estimation of the noisy component of anatomical backgrounds.
Bochud F.O., Valley J.F., Verdun F.R., Hessler C., Schnyder P., 1999. Medical physics, 26 (7) pp. 1365-70. Peer-reviewed.
 
Measurements of human observer responses with a 2-AFC experiment
Bochud François O., Valley Jean-François, Verdun Francis R., Hessler Christian, Schnyder Pierre, Abbey Craig K., 1999. Zeitschrift für Medizinische Physik, 9 pp. 48-54. Peer-reviewed.
 
Radiation doses delivered to radiologists during contrast-enhanced helical-CT examinations
Theumann N. H., Verdun F. R., Valley J. F., Capasso P., Schnyder P., Meuli R. A., 1999. European Radiology, 9 (9) pp. 1919-1922. Peer-reviewed.
Comparison of subjective and objective evaluation of screen-film systems for chest radiography
Moeckli R., Verdun F.R., Bochud F.O., Valley J.F., Hessler C., Schnyder P., 1998. Radiation Protection Dosimetry, 80 (1-3) pp. 265-268. Peer-reviewed.
 
Dose evaluation in fluoroscopy
Verdun F. R., Capasso P., Valley J. F., Schnyder P., 1998. Radiation Protection Dosimetry, 80 (1-3) pp. 139-141. Peer-reviewed.
European Survey of Image Quality Assessment Methods Used in Mammography
Verdun F.R., Moeckli R., Valley J.F., Bochud F., Hessler C., Schnyder P., 1998. Radiation Protection Dosimetry, 80 (1-3) pp. 73-76. Peer-reviewed.
 
Levels of image quality and dose in mammography: State of the art in Europe | Niveaux de qualites d'image et de doses en mammographie: La situation en Europe
Verdun Francis, Hessler Christian, Moeckli Raphaël, Bochud François, Vauthey Jean-Luc, Valley Jean-François, 1997. Sein.
 
The importance of anatomical noise in mammography
Bochud François, Verdun Francis, Valley Jean-François, Hessler Christian, Moeckli Raphaël, 1997. dans Proceedings of SPIE - The International Society for Optical Engineering.
 
Image quality and dose in spiral computed tomography
Verdun F. R., Meuli R. A., Bochud F. O., Imsand C., Raimondi S., Schnyder P., Valley J. F., 1996. European Radiology, 6 (4) pp. 485-488. Peer-reviewed.
 
Survey on image quality and dose levels used in Europe for mammography.
Verdun F.R., Moeckli R., Valley J.F., Bochud F., Hessler C., 1996. The British journal of radiology, 69 (824) pp. 762-8. Peer-reviewed.
 
Determination of the Speed of Medical Radiography Screen-Film Systems
Verdun F. R., Bochud F. O., Valley J. F., Thanh O. L., 1995. Radiation Protection Dosimetry, 57 (1-4) pp. 257-261. Peer-reviewed.
 
Assessment of MR image deformation for stereotactic neurosurgery using a tagging sequence
Meuli R. A., Verdun F. R., Bochud F. O., Emsley L., Fankhauser H., 1994. AJNR. American Journal of Neuroradiology, 15 (1) pp. 45-49. Peer-reviewed.
 
Volume Rendering Techniques Applied to Magnetic Resonance Angiography
Aroua A., Bochud F.O., Maeder Ph.P., Meuli R.A., Valley J.-F., Verdun F.R., 1994. Zeitschrift für Medizinische Physik, 4 (1) pp. 41-45. Peer-reviewed.
 
Subjective and Objective Evaluation of Chest Imaging-Systems
Verdun F. R., Bochud F., Depeursinge C., Desponds L., Grecescu M., Hessler C., Raimondi S., Valley J. F., 1993. Radiation Protection Dosimetry, 49 (1-3) pp. 91-94. Peer-reviewed.
 
Beating the Nyquist Limit by Means of Interleaved Alternated Delay Sampling - Extension of Lower Mass Limit in Direct-Mode Fourier-Transform Ion-Cyclotron Resonance Mass-Spectrometry
Verdun F. R., Ricca T. L., Marshall A. G., 1988. Applied Spectroscopy, 42 (2) pp. 199-203. Peer-reviewed.
 
Effects of Noise, Time-Domain Damping, Zero-Filling and the Fft Algorithm on the Exact Interpolation of Fast Fourier-Transform Spectra
Verdun F. R., Giancaspro C., Marshall A. G., 1988. Applied Spectroscopy, 42 (5) pp. 715-721. Peer-reviewed.
 
Increased Sensitivity in Laser Microprobe Mass Analysis by Using Resonant 2-Photon Ionization Processes
Verdun F. R., Krier G., Muller J. F., 1987. Analytical Chemistry, 59 (10) pp. 1383-1387. Peer-reviewed.
 
An Experimental-Study of Ion Motions in A Double Cell Ft/Icr Instrument
Giancaspro C., Verdun F. R., Muller J. F., 1986. International Journal of Mass Spectrometry and Ion Processes, 72 (1-2) pp. 63-71. Peer-reviewed.
 
Mass Discrimination Based on Longitudinal Ion Motion in A Double-Cell Fourier-Transform Ion-Cyclotron Resonance Mass-Spectrometer
Giancaspro C., Verdun F. R., 1986. Analytical Chemistry, 58 (9) pp. 2097-2099. Peer-reviewed.
 
Coupling A Tunable Dye-Laser to A Lamma-500 Microprobe
Krier G., Verdun F., Muller J. F., 1985. Fresenius Zeitschrift fur Analytische Chemie, 322 (4) pp. 379-382. Peer-reviewed.
 
Ionization of Organic-Crystals with A Tunable Dye-Laser Connected to A Lamma Instrument
Muller J. F., Krier G., Verdun F., Lamboule M., Muller D., 1985. International Journal of Mass Spectrometry and Ion Processes, 64 (2) pp. 127-138. Peer-reviewed.
 
Ionization of Materials with Tunable Dye-Laser
Muller J. F., Verdun F., Krier G., Lamboule M., Gondouin S., Tourmann J. L., Muller D., Lorek S., 1984. Comptes Rendus de l'Académie des Sciences Serie II, 299 (16) pp. 1113-&. Peer-reviewed.
 
Study of the Detection of Polycyclic Aromatic-Hydrocarbons at the Microparticle Level Using the Impact Laser Microprobe Lamma
Verdun F., Muller J. F., 1984. Journal de Physique, 45 (NC-2) pp. 819-822. Peer-reviewed.